ScanBox

Runners for Eutectic Plate

Plateholder for :

free shipping
Free shipping for Online Orders over $150 + gst*

Product Description

ScanBox Eutectic Plate Holder helps you to attach Eutectic Plates 530×325 to the top of the box space in a Banquet or Ergo Line.

ESB31 - Attach 2 pieces of Eutectic Plate 530×325 to the top of the box space in a Banquet Line.

ESB32 - Attach a single piece of Eutectic Plate 530×325 to the top of the box space in an Ergo Line.

The Eutectic Plate Holder for Ergo and Banquet Line can easily and conveniently be hung on existing runners and requires minimum space inside the box. Perfect for getting extra cooling capacity in a cold box during transport or transform an insulated or hot box into a cold box. This item is labelled as an accessory which means that it doesn’t have to be mounted in our factory, but can easily be attached to existing products and coming orders.

Why use eutectic plates?

Eutectic plates add cooling capacity for ambient, cold and hot boxes. Use it to transform an ambient or hot box into a cold box for temporary cooling operations. If you have long transports without access to electricity, a eutectic plate can easily and conveniently offer extra cooling support. Our new eutectic plate holder is an accessory which means it doesn’t have to be mounted, but just added on top of the runners (se video below). This is a very flexible solution that requires minimal space inside the box. In fact, you can utilize full pan capacity in your box.

How do I get the maximum cooling capacity out of the eutectic plate?

The eutectic liquid must be completely frozen (solidified) before you can use the eutectic plate. If you can hear or see the liquid moving, it means that there are not enough frigories in the eutectic liquid and the cold capacity will be reduced. You can control the freezing of your cold accumulators by shaking the plate. Any movement resulting from a liquid or semi-liquid state indicates that the eutectic solution is not deeply frozen.

At which temperature must the plate be frozen?

The freezing temperature of the eutectic plate must be at least 5°C below the eutectic liquid melting temperature. Our eutectic plates has a liquid melting temperature of -3°C which means that it must be frozen at least at -8°C.

How long is the freezing time for the eutectic plates?

The freezing time can vary from 6 to 24 hours depending on the refrigeration unit used. Permanently keeping a second set of eutectic plates in the refrigeration unit ensures the immediate availability of the cold.

How can I speed up the freezing time of the eutectic plates?

In order to speed up the freezing process, the eutectic plates must be separated from one another in the freezer, at least by 3 cm. If they are piled up, the cold air cannot circulate between them, which significantly increases the freezing time.


The ScanBox food transport carts are elegant, versa­tile and lightweight. Some of them are in fact half the weight of comparable competing products. They are nevertheless designed for "heavy duty". All our carts, including the high capacity Duo varieties, are very easy to operate and transport. ScanBox products are developed and built in Sweden to the very highest standards. 

 